Salgrom-X Spider 12,5kg

Code:

0401

Firefighting capability:

≤ 35 m3

Dimensions:

504 x 404 x 145 mm

Type:

Spider

Classes of fire:

ABCDF

Extinguishing agent:

Aerosol

Weight:

12,5kg

Material:

Steel

More information

>

SALGROM-X SPIDER 12,5KG
Salgrom-X Spider is a fully self-contained aerosol fire extinguishing system with very high performance that enhances the safety of transport, storage and operation in industry. As soon as the extinguishing system detects an elevated temperature in the space, it starts the extinguishing process within seconds. The fire aerosol system has no external control unit, no power supply and operates completely without wiring, ensuring operation even in the event of a power failure. The innovative Salgrom-X Spider is designed for installation in, for example, marine, land-based shipping containers, electrical and data rooms and other enclosed spaces up to 35m3. The space in which the aerosol extinguishing system is installed must be enclosed and tight, otherwise the device will not work. The material of this self-contained aerosol extinguishing system is powder coated high strength steel.

PRODUCT FEATURES
Automatic 93°C trigger
Pre-alarm information 55°C/75°C/105°C
Maximum extinguishing capacity 35m3
Optional intelligent data transmission and remote management
Easy relocation
Quick and easy installation

HOW THIS SELF-CONTAINED AEROSOL EXTINGUISHING SYSTEM WORKS
Using advanced technology, the autonomous extinguishing system instantly identifies hazards. Once activated, an aerosol is generated from the system that reduces temperature and eliminates flames in seconds without damaging sensitive equipment or leaving marks on materials.

INSTALLATION
The fire extinguishing system weighs only 12.5 kg, so it can be installed on the wall using the integrated magnets, screws or quick-coupling attachment. The extinguishing system will then remain functional for 5 to 10 years depending on conditions.

AREAS OF APPLICATION
Marine, cargo, storage and shipping containers, traffic management systems and radar and base stations, electrical equipment buildings and fiber optic network cabinets, energy storage systems and telecommunications stations, hazardous materials and battery storage facilities, defence technical facilities, equipment containers and mobile platforms, difficult to access or remote objects located in terrain, sites with a high risk of fire.

FIRE CLASSES
A: fires of solid substances, mainly of organic origin, the burning of which is usually accompanied by burning
B: fires involving liquids or substances in the liquid state
C: fires of gases
D: fires involving combustible metals
F: fires involving frying oils and fats